product-img
  • small-img

PFM922I-6UN-C

UTP CAT6 Cable

> 305.0 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> Manufacturing excellence

> Customized PVC outer sheath; meet CE CPR Eca flame retardant class certified

> 10-year warranty

  • āļĢāļēāļĒāļĨāļ°āđ€āļ­āļĩāļĒāļ”āļ„āļļāļ“āļĨāļąāļāļĐāļ“āļ°
  • āļ­āļļāļ›āļāļĢāļ“āđŒāđ€āļŠāļĢāļīāļĄ
  • āļ”āļēāļ§āļ™āđŒāđ‚āļŦāļĨāļ”
  • Conductor

    Material

    CCA(Copper content 22%–31%)

    Diameter

    0.57 mm Âą 0.01 mm

    American Wire Gauge

    23AWG

    Insulation

    Material

    HDPE

    Min. Average Thickness

    0.21 mm

    Diameter

    1.02 mm Âą 0.06 mm

    Color (4 Pairs)

    Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

    Separator

    Material

    PE

    Specification

    Translucent 4.5 × 0.4 mm

    Rip Cord

    Material

    Polyester

    Specification

    500D

    Sheath

    Material

    PVC

    Min. Average Thickness

    0.5 mm

    Diameter

    6.5 mm Âą 0.3 mm

    Color

    Orange

    Electrical

    Max. DC Resistance of a Single Conductor

    11.5ÎĐ/100 m

    Min. Insulation Resistance

    5000MÎĐ·km

    Max. DC Resistance Unbalance

    2% (pair intra), 4% (pairs inter)

    Dielectric Strength

    No breakdown with 1KV DC for 1 min

    Transmission

    Characteristic Impedance

    100 Âą 15ÎĐ

    Near End Cross Talk

    â‰Ĩ39.30 dB/100 m@250 MHz

    Max. Attenuation

    34.8 dB/100 m@250 MHz

    Return Loss

    â‰Ĩ17.3 dB/100 m@250 MHz

    Mechanical

    Tensile Strength

    Sheathâ‰Ĩ13.5 MPa, insulationâ‰Ĩ16 MPa

    Elongation at Break

    Sheathâ‰Ĩ150%, insulationâ‰Ĩ300%

    Installation Bending Radius

    >8 times of outer cable diameter

    Conductor Elongation at Break

    â‰Ĩ10%

    Environmental

    Shrinkage of Insulation

    â‰Ī5%

    Color Migration Resistance of Insulation

    No migration

    Sheath Tensile Strength and Elongation at Break after Aging

    â‰Ĩ12.5 MPa, â‰Ĩ100%

    Low Temperature Bending Test

    No cracking after the test

    Heat Shock Test

    No cracking after the test

    Operation Temperature

    –20°C to +60°C (–4°F to 140°F)

    Installation Temperature

    0°C to +50°C (32°F to 122°F)

    Storage Temperature and Humidity

    –10°C to +40°C (14°F to 104°F), <60% (RH)

    Security

    Vertical Fire Propagation Test

    Comply with IEC 60332-1-2

    Packaging

    Length

    305.0 m (1000.66 ft) Âą 1.5 m (4.92 ft)

    Packaging Dimensions

    390.0 mm x 390.0 mm x 247.0 mm (15.37"x15.37"x9.73") (L × W × H)

    Packaging Method

    305.0 m (1000.66 ft) a carton, one protection carton with 2 cartons inside

    Net Weight

    â‰Ĩ9.2 kg (20.28 lb)

    Gross Weight

    â‰Ĩ10.2 kg(22.49 lb)

    Executive Standard

    Executive Standard

    Q/DXJ 067-2019

    Certification

    Certification

    CPR Eca