| Flasher |
Standard hardware flasher, independent on program control |
| Flashing Yellow |
Flashing yellow during failure |
| Channel |
4 output boards, supporting 24 channels |
| Types of Phases |
16 parent phases and 16 overlap phases. Supports repeat running of parent phase, meeting requirements of repeat timing in a cycle and independent parameter settings |
| Signal Group Output |
8 groups |
| Cycle Scheme |
Up to 54 cycle schemes |
| Multi-period Timing |
Up to 112 daily schemes, 48 pretimed periods, 20 weekly schemes, 16 daily dispatch schemes, and 16 special dispatch schemes |
| Pedestrian Crossing |
(standard) 0 pedestrian button detector inputs, (optional) 1 pedestrian detection board that supports 8 pedestrian button detector inputs, and (optional) 2 pedestrian detection boards that support 16 pedestrian button detector inputs. A total of 2 pedestrian and vehicle detector boards are optional |
| Coil |
(standard) 0 coil inputs, (optional) 1 vehicle detection board that supports 8 coil inputs, and (optional) 2 vehicle detection boards that support 16 coil inputs. A total of 2 pedestrian and vehicle detector boards are optional |
| Actuated Control |
Up to 64-channel traffic enforcement cameras. 2 detecting devices (include camera, coil, and more) can be used for detecting 1 lane |
| Signal Control Mode |
Supports manual control, pre-timed control, cableless link control, human/vehicle actuated control, adaptive control, and special mode control. |
| Manual Control |
Side door manual control and remote control through side door or host computer to meet on-site requirements |
| Change of Control Modes |
Natural change between manual control and automatic control (pretimed control, actuated control, and more) |
| Cableless Link Control |
Yes. Coordination control is realized by setting offset |
| Special Mode Control |
Supports flashing yellow, all red, and light off control |
| Temporary Scheme |
Supports configuring or clearing temporary schemes through platform |
| Waiting Area |
Yes |
| Default Light Color |
Default light colors include all red, flashing yellow, solid yellow, light off, and solid red. Default light color displays when no phase is running in a scheme or no channel is configured |
| Special Status |
Supports special status control of traffic lights, such as all red, flashing yellow, solid yellow, light off, and solid red |
| Count down |
Self-learning, pulse, and RS-485 communication countdown timers. Supports setting baud rate when using RS-485 communication countdown timer |
| Timing |
Manual Time Adjustment;Network Sync;GPS;NTP |
| Phase |
Separately set parameters of phase for cycle schemes and repeated phase. Each cycle scheme can be set with different phase parameters |
| Signal Control Duration |
Adjustable |
| Auto Phase Timing |
When adjusting a cycle, set the total cycle length, and the phases will be timed automatically according to the split (the ratio of phase time and cycle length in a cycle) |
| Failure Detection |
Degradation mechanism in case of green conflict and light fault; independent hardware yellow flashing control; fault information upload and search |
| Access Control Monitoring |
Supports door open/close monitoring and reporting |
| Network Control |
Communicates with host computer or central platform through network; supports setting temporary scheme and special tasks on platform |
| Information Security |
Identity authentication, control order verification, update verification of operation parameters, and broadcast storm protection |
| Parameters Configuration |
Supports setting control parameters on PC client and remote server |
| Update |
Network upgrade, USB/TF card upgrade |
| Lighting |
Yes, Supports door open/close and lighting linkage |
| Auto Maintenance |
Yes |